Search results for " ELECTROCHEMICAL SENSOR"
showing 10 items of 15 documents
Silver based sensors from CD for chloride ions detection
2021
This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this tech…
Electrochemical detection of chloride ions using Ag-based electrodes obtained from compact disc
2022
Abstract In this work electrochemical sensors fabricated from compact disc material (waste or new) are used to quantify chloride ions in different types of samples. All three electrodes, working, counter, and pseudo-reference electrodes, were fabricated from the compact disc and directly used. Different parameters were studied in order to demonstrate the possibility of using this waste material for efficient and low-cost electrochemical sensors. Chloride sensing performance was evaluated using linear scan voltammetry as the detection technique. A sensitivity of 0.174 mA mM−1 cm−2 with a limit of detection of 20 μM and excellent selectivity against many interferents was observed. Selectivity…
Electrochemical detection of dopamine with negligible interference from ascorbic and uric acid by means of reduced graphene oxide and metals-NPs base…
2021
Abstract Dopamine is an important neurotransmitter involved in many human biological processes as well as in different neurodegenerative diseases. Monitoring the concentration of dopamine in biological fluids, i.e., blood and urine is an effective way of accelerating the early diagnosis of these types of diseases. Electrochemical sensors are an ideal choice for real-time screening of dopamine as they can achieve fast, portable inexpensive and accurate measurements. In this work, we present electrochemical dopamine sensors based on reduced graphene oxide coupled with Au or Pt nanoparticles. Sensors were developed by co-electrodeposition onto a flexible substrate, and a systematic investigati…
Reduced graphene oxide decorated with metals nanoparticles electrode as electrochemical sensor for dopamine
2019
Dopamine (DA) is one of the most important neurotransmitters that influences the processes that involve memory, sleep, mood, learning among others [1]. In fact, in the last years, dopamine concentration in human body fluids has been related to some neurodegenerative diseases, such as Parkinson and Alzheimer's diseases [2]. The possibility to have a bio-marker for these disease is of extreme importance because, disease related with dementia, are diagnosed when they are already developed and their management become almost impossible. The possibility to continuously monitor DA level in fluids, such as blood and urine, could accelerate the early diagnosis of these diseases. The principal analyt…
Wearable sensor for real-time monitoring of hydrogen peroxide in simulated breath
Electrochemical Quantification of H2O2 Released by Airway Cells Growing in Different Culture Media
2022
Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham’s F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrode…
A Comparative Study of Poly(Azure A) Film-Modified Disposable Electrodes for Electrocatalytic Oxidation of H₂O₂: Effect of Doping Anion.
2018
In the present paper, poly(azure A) (PAA) films were electrosynthetized in the presence of different doping anions on disposable screen-printed carbon electrodes (SPCEs). The anions used included inorganic monoatomic (chloride and fluoride), inorganic polyatomic (nitrate and sulfate) and organic polyatomic (dodecyl sulfate, DS) species. The coated electrodes thus obtained were characterized by electrochemical techniques and SEM. They showed improved electrocatalytic activities towards hydrogen peroxide oxidation compared to that of a bare SPCE. In particular, the insertion of DS anions inside PAA films provided a special sensitivity to the electrocatalysis of H2O2, which endowed these elect…
FABBRICAZIONE DI SENSORI ELETTROCHIMICI NANOSTRUTTURATI PER APPLICAZIONI NELL’INDUSTRIA ALIMENTARE E BIOMEDICHE
2023
DOPAMINE ELECTROCHEMICAL SENSOR BASED ON REDUCED GRAPHENE OXIDE AND METAL NANOPARTICLES
2019
Dopamine (DA) is one of the most important neurotransmitters released from the brain, and is involved in many different biological processes. This neurotransmitter influences the processes that involve memory, sleep, mood, learning, and so on. Besides, in the last years, dopamine concentration in human body fluids has been related to some neurodegenerative pathologies, such as Parkinson and Alzheimer’s diseases [1]. It is well known that these pathologies are due to the formation of amyloids plaques that block part of the brain. Many literature data reports that DAergic neurons (areas of midbrain where DA is synthesized) shows a different activity when amyloid plaques are present with a con…
Phosphate ions detection by using an electrochemical sensor based on laser-scribed graphene oxide on paper
2023
In this work, electrodes based on laser-scribed reduced graphene oxide were fabricated using filter paper as the substrate. To fabricate the electrodes, a water suspension of graphene oxide was filtered to produce a continuous and uniform film of graphene oxide on the filter paper surface. Subsequently, a CO2 laser was used to "write" the working, counter and reference eelctroes by reducing graphene oxide in specific areas to define complete sensors. Referecnce electrodes were then coated with a commercial Ag/AgCl conductive paste to produce a quasi Ag/AgCl reference. As fabricated devices were employed as electrochemical sensors for detection of phosphate ions in water by employing the mol…